Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

infectious waste pyrolysis machine chinalarge animal incinerators

Major components are – Ethanol, Paraffin, Silicon, Aluminium chloro hydrate, Bentone ,LPG

quote for incinerators for industrial chemical wastes treatment,

1 burning rate must be Average 30kgs\h
2 inside of chamber material must be refractory concrete cement
3 it works in three system diesel oil\ Natural gas or LPG
4 voltage must be 220V

5 inside temperature first must be 1000c  and second must be 1200c
6 pipe length must be 20 M

Our requirements are  for 125 kg/hr and 42 kg/hr, please send quote with catalog for both options
We are currently dealing in Defense Related Equipment, Construction Assistance and Medical Equipment, Modular Solutions

for Hospitals, Waste Management System, CSSD, Hospital Furniture and Services. We are based in the Capital city of

Pakistan i.e. Islamabad ,where there are all the head offices of Military and Govt. institutions. We have the capacity to

Participate in tenders and we also have a strong network of energetic/active dealers and sales staff in Pakistan and

Afghanistan.
5 incinerator 15 kg the specifications High temperature incinerator​99% combustion efficiency Temperature up to 1200°C or

Smoke and smell free Excellent heat retention Electric powered​ Fast heatup times Temperature Up to 1200°C or as required

Capacity​15 Kg Burning Efficiency 98% Noise- <78db Power – Electric Chamber​Single / Dual chamber Safety Alarm Emergency

vent Monitoring device​ Air Pollution Control Device​ CE and ISO Certified

I ‘d like to ask you about a power plant by burning waste. We have many of camps for displaced people in Syria, and we

want to buy a plant to generate electricity by municipal waste incineration Please send me an offer or any details.

low-cost medical waste incinerator

Stack:
Type:  Wire Supported
MOC:  Mild Steel of ISstd
Height :3 Meters or more
• PROCESS AT LEAST 1 METRIC TON OF WASTE PER DAY
• OPERABLE BY 1 PERSON, WITH NO TRAINING REQUIRED
• REGULAR MAINTENANCE CAN BE COMPLETED BY 1 PERSON WITH LIMITED TRAINING
• REGULAR MAINTENANCE SHOULD NOT EXCEED 1-HOUR PER DAY
• COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS
• ABILITY TO INCINERATE WASTE PETROLEUM, OILS, AND LUBRICANTS
• TEMPRATURES DURING THE COMBUTION PROCESS MUST EXCEED 1,500 °F FOR AT LEAST 1-HOUR
• CAN BE TRANSPORTED TO AND FROM DEPLOYMENT LOCATION IN A 20-FOOT OR SMALLER SHIPPING ISO CONTAINER
• CAPABLE OF 24 HOURS OF CONTINUOUS USE
• AUTOMATIC LOADING SYSTEM
• AUTOMATED ASH REMOVAL SYSTEM
• GAS SCRUBBING SYSTEM
• 95% REDUCTION OF SOLID WASTE
• OPERABLE WITH DIESEL, JP8, OR FUEL OIL
• CAPABLE OF BURNING 4 UNITS OF WASTE PER UNIT OF FUEL
• ABLE TO INCINERATE COMBUSTIBLE WASTE TO INCLUDE: PAPER, PLASTIC, CARDBOARD, FOOD, USED OILS, SLUDGE, OILY RAGS, AND

WOOD PALLETS.
• NO PRE-TREATMENT OF WASTE REQUIRED
• VENDOR REPAIR OFFERED AT POINT OF SHIPMENT
• FIVE (5) YEAR COMPONENT WARRANTY FROM DATE OF ACCEPTANCE
We are an aerosol manufacturing company.. Our products includes Deodorants, Anti perspirant deodorants ,air freshners,

Insect killers etc..

china incinerator manufacturer and exporter

Primary Combustion Chamber
Waste Charging Door: Provided with refractory lining with sealing gaskets
Ash Removed Door: Provided with refractory lining with sealing gaskets
Outer Body MOC: Mild Steel, 5mm
Primary Chamber: Stainless Steel
Operating Temperature :800. ± 50◦C
Insulation: Insulation Brick
Heating Elements Type: Kanthal Al Grade
Power Consumption: 75 KW ( Initial Load )
Electrical Supply :3 Phase 440 Volt
Control Panel
MOC: Mild Steel Power Coated
No. of Temp: Controllers : 2 Nos
Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase.
I.D.Fan
Type: Centrifugal Type
MOC: Mild Steel
Capacity:2 HP/3Phase
Make of Motor: Kirloskar /Havells/Crompton
Combustion Air Fan
Type: Centrifugal Type
Capacity: 1HP/3Phase
Make of Motor: Kirloskar /Havells/Crompton

incinerator manufacturer in china

1. Is the residence time more than 2 seconds?
2. Is the primary and secondary air preheated?
3. Could it be provided as a continuous system?
4. Is there a monitoring system for operational parameter? (temperature)
5. Is there a data logging system?
6. Does it provide for control interventions to adjust waste feed, grate speed, and temperature, volume and distribution

of primary and secondary air?
7. Does it include auxiliary burners?
8. Does it include system that automatically stops waste feeding when combustion parameters are not appropriate?
9. Is it possible to have an automatic bottom ash unloading system?
1. Is the primary and secondary air preheated?
2. Could it be provided as a continuous system?
3. Is there a data logging system?
4. Does it provide for control interventions to adjust waste feed, grate speed, and temperature, volume and distribution

of primary and secondary air?
5. Does it include auxiliary burners?
6. Does it include system that automatically stops waste feeding when combustion parameters are not appropriate?
7. Is it possible to have an automatic bottom ash unloading system?
Incinerator
Rated Capacity: 100/KG/Hr
Type of Design: Double Chambered
Mode of Heating: Heating Elements

waste incinerator manufacturer in china

  1. Burning rate: 250 Kg/hr.
  2. It should be able to Operate not Less than 10 hours/day
  3. This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…
  4. Design Specification: Types A, B, C, D, and E of medical waste
  5. “PYROLYTIC” combustion, by controlling the gasification of waste.
  6. The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings.
  7. It should be able to reduce the volume of wastes by 98%.
  8. It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.

The incineration should be completely free from visible smoke as well as offensive odours.

  1. The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg
  • The Temperatures of combustion:Minimum will be 850oC and max 1400oC
  • Post combustion: >1100o
  1. The Internal diameter of the Chimney: Ø 400mm² and its height: 8 Meter
  2. The Volume of the combustion chamber: Not Less Than 2.3 M³
  3. Burner operation should be Automatic On/Off
  4. Fuel : diesel, LPG, Natural Gas, Bio fuel
  5. The supplier must provide  necessary information for the best of  the installation

This incinerator with “PYROLYTIC” combustion must have:

  1. A combustion chamber of waste:

* Perfectly tight door for the manual loading of waste.The loading should be Manual, Batch Load,

* A burner of lighting which the use is limited to the ignition of waste.

* Top Loading loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.

* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminum and insulates bricks in order to assure a minimum temperature on   the outside sheet metal.

* Composition of the refractory;

  • Refractory concrete :
    • . Thickness : ≥100 mm
    • . Nature: 42% of Al203
  • Insulate in fibrous panels :
    • . Thickness: ≥75 mm
  • Nature: Calcium silicate.

* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Plate of combustion in Carborundum, avoiding the fixing of glass and slags.

  1. Load Method: Top Loading

 

  1. A chamber of post combustion of gases

* A burner of combustion of gases,

* A device of injection of air allowing a total recombustion of gases,

* A device of air inlet of cooling of waste gases,

* A sheath of evacuation of the gases burnt.

* Carcass in strong sheet steel with support of connection.

* Composition of the refractory;

  • Refractory concrete :
    • Thickness : ≥180 mm
    • Nature: 65% of Al203
  • Insulate in fibrous panel :

Clover's Social Media